Reducing power supply noise in VCO's
Pactical Techniques
It is always a good design philosophy to provide RF bypassing of power and dc control lines to
the VCO. This is indeed the case when the VCO is located some distance away from the power
supply. RF chokes and good bypassing capacitors of approximately 1000 pf to 0.1 F is
recommended at the DC supply lines. This will minimize the possibility of feedback between
stages in a complex subsystem. Improved bypassing may be provided by incorporating an active
filter circuit shown in figures 1 and 2.
Figure 1
Active bias circuit for improved power line filtering
Figure 2
Active bias circuit for providing more flexibility in setting Vcc f r a given VCO
This type of RF bypassing is recommended for applications requiring a high level of noise
suppression for externally generated noise signals. In most cases, the performance of the circuit
in Figure 1, which is current biased, will be adequate and will have the advantage of better low
frequency bypassing performance for a given value of base capacitor, fewer components, and
lower power consumption.
It is only necessary to use the circuit in Figure 2 when the higher isolation offered by a larger VCC
is required. The circuit in Figure 2 is voltage biased. In this case, the circuit in Figure 2 offers a
more stable operating point.
Noisy power supplies may cause additional noise. Power supply induced noise may be seen at
offsets from 20 Hz to 1 MHZ from the carrier. If the VCO is powered from a regulated power
supply, the regulator noise will increase depending upon the external load current drawn from the
regulator. The phase noise performance of the VCO may degrade depending upon the type of
regulator used, and also upon the load current drawn from the regulator. To improve the phase
noise performance of the VCO under external load conditions, one or more of the following steps
may be taken:
Figure 3
Typical connection diagram. Power supply decoupling provides improved noise
Figure 4
Typical connection diagram. Additional RF decoupling provided by LC type filter improves
power line filtering.