Understanding Mixers
Often a mixer data sheet does not specify intercept point, so a rule-of-thumb estimate can easily
be made by examining the 1dB compression point. As RF input level is increased, there is a point
where the conversion loss will increase. A convenient point of reference is a l dB compression
point. As RF input is increased, IF output should follow in a linear manner. However, after a
certain point, the IF output increases at a lower rate until the mixer output becomes fairly
constant. When the IF output cannot follow the RF input linearly, and deviates by 1 dB, this
point is called the 1 dB compression point. Now, the conversion loss is 1 dB higher than it was
when the RF input signal was smaller. The importance of this figure is its utility in comparing
dynamic range, maximum output and two-tone performance of various mixers.
As a rule-of-thumb, the intercept point is approximately 10 to 15 dB higher than the 1 dB
compression point; at low frequencies about 15 dB, and at higher frequencies about 10 dB. See
Fig. 7.
how to measure mixer performance
A manufacturer with integrity does not play the "numbers game" when preparing specification
data on his product line. Mini-Circuits' policy for product measurement and specification is
straightforward - present the honest facts so the design engineer can evaluate product data for his
circuit and system requirements and arrive at a proper design decision.
A 50-ohm broadband system is used for all factory measurements. It offers the customer a
convenient and consistent means to obtain correlation with data prepared by Mini-Circuits.
conversion loss measurements
For conversion loss measurements, Fig. 8a, fixed attenuator pads are connected to all three ports
so the mixer sees 50 ohms at the frequency of interest and all harmonics. An RF input level of -11
dBm is deliberately selected. Here's why, assuming a typical 6 dB conversion loss, the IF
output would be -17 dBm. Mini Circuit's mixers provide LO-IF isolation typically in the order
of 50 to 60 dB. Normally, the LO input is +7 dBm and thus with 50 dB isolation, the LO leakage
level of -43 dBm would be much lower than IF output. Therefore the RF input level is high
Figure 7
The 1 dB compression point is an indication of a dbm's dynamic range and maximum power capabilities.
enough to operate the mixer in its linear range and not low enough to allow LO leakage to
destroy the integrity of the measurement.
For the IF power level measurement, a filter is included before the broadband RF voltmeter, to
reject all responses other than the desired IF. When a crystal filter is used, LO leakage would
have no effect on the conversion loss measurement since it would not reach the RF voltmeter.
two general techniques for measuring isolation
There are two general techniques for measuring isolation, both requiring 50 ohm terminations at
the unused ports. When measuring LO-RF isolation, see Fig. 8(b), a pad is placed between the
generator and DBM to ensure a 50-ohm-impedance. Also, a 50-ohm termination is connected to
the IF port and the power at the RF port is measured to obtain the isolation performance.
When measuring isolation from RF-IF or RF-LO, the power applied at the RF port is set at a high
level to make sure the diodes have sufficient drive power. This RF power level will be higher
than encountered in actual DBM usage. However, the measurement results can be considered
quite accurate.
The RF voltmeter technique actually produces isolation specs that are conservative since many
applications normally involve narrowband circuits and filters that would eliminate harmonics. By
assuming everything measured on the RF voltmeter is due to the fundamental and that harmonics
are not present, mixers supplied by Mini-Circuits perform better than expected from the data
sheet specs.
Replacing the RF voltmeter by a spectrum analyzer enables the following improvement in
measurement integrity. First, the power at the fundamental frequency of measurement can be
observed. Now, for broadband applications, the effects of harmonics can be judged. For narrow-band applications, only the fundamental need be considered. By using the spectrum analyzer
technique, the design engineer can avoid over specifying his DBM isolation requirement with
subsequent cost savings.
Here's another important advantage of the spectrum analyzer technique. When RF-IF or RF-LO
measurements are made, the RF and LO levels can now be set at the normal operating level
under which the DBM will be used.
VSWR measurements
VSWR measurements are made under the same dynamic conditions that the mixer would
encounter in practice, see Fig. 8(c). First, let's consider VSWR measurement at the RF port. An
LO signal is applied to its port and the unused IF port is terminated in 50 ohms. The RF
generator supplies an input level corresponding to linear mixer operation. With the double-
balanced mixer disconnected from the directional coupler, a reference level is obtained (all the
RF power is reflected back). The amount of reflected signal depends on the directional coupler
used; a 20 dB coupler would establish a reference level 20 dB below the RF input. Next, the
mixer is connected to the output of the directional coupler. The spectrum analyzer acts as a
narrow-band filter and allows observation at the RF input frequency. The RF power reflected
back from the mixer is displayed and can be measured by the calibrated scale on the spectrum
analyzer.
The VSWR at the IF port is measured in a similar fashion. In this case, the RF port is terminated
in 50 ohms.
Broadband mixers, it should be noted, exhibit a different VSWR characteristic at different
frequencies. Factors causing this include circuit resonances and changes in diode impedances as
the LO power level changes. Also of importance is the fact that the input impedances of the
various ports are load dependent, even though they are isolated from each other. At high
frequencies, this effect is more noticeable since isolation tends to drop as frequency increases.
Test measurement steps for (a) conversion loss, (b) isolation, (c) VSWR and (d) two-tone,
third-order distortion.
two-tone, third-order intermodulation distortion
Two-tone, third-order intermodulation distortion takes place when two incoming signals arrive at
the mixer RF port and interact. The signals resulting from the interaction may be objectionable
within the IF response.