Mobile HV Generator
II:
Last
updated: 29. Feb 2000
Changes:
...
DISCLAIMER: This device
is dangerous and can cause damage of property and health or even death.
I cannot take any responsibilty for any damage possibly resulting from
using the device described here, or following the instructions given (nor
for anything else you do!). So be careful, follow safety instructions and
use common sense.
click to see larger version
(~100kByte)
The differences between the
Mobile
HV Generator and the Mobile HV Generator II are:
higher fireing frequency =>
it looks like an arc
better and smaller oscillating
circuit => more room for other stuff
the circuit is firing after
reaching a specified voltage => no voltage regulating circuit needed
less output voltage but high
firing frequency
I'm using the same inginition/trigger
coil [TR2] which I built for the first Mobile
HV Generator. The transformer [TR1] is a special fotoflash transformer.
I bought it from a mail order firm called: Conrad
Electronic. The transformer's ordering number is: 582263-11. It costs
3.63 Euro, without shipping.
You can use ervery other
NPN transistor instead the BD135 which can held about 2 Ampere.
Insulation tape between ervery
HV layer of the TR2 is not withstanding the HV pulses, because I killed
my Tr2 with this circuit! Spray acrylic laquer on every HV-Layer and use
the best insulation tape you can get.
Pictures of the parts:
0.33µF
cap with 1MOhm resistor
600V
spark gap (gas discharge tube)
Trafo
- TR1
.
Things to do:
Build an auto-firing circuit
(with a thyristor and a diac??) which you can use instead the 600V spark
gap.
.
Helpful Hints:
You can use another diode than
the 1N4007 (between TR1 and the 600V spark gap). The voltage rating must
be 1kV min and the diode should be fast enough for the high frequency (15kHz).
You can find such diodes in switched mode power supplies.
.
.
[Back
to Mobile HV Generator Index]
[Back
to Jochen's HV page]
Christian
Auer
CA1@GMX.NET