| NTE Type No. |
Repetitive Peak Forward Off-State Voltage (Volts) |
RMS On-State Current (Amps) |
Surge Current (Amps) |
Maximum Ratings | Typical Turn-Off Time (µs) |
Rate of Rise Voltage (V/µs) |
Package Style | |||
| On-State Voltage (Volts) |
Gate Trigger Current (mA) |
Gate Trigger Voltage (Volts) |
Holding Current (mA) | |||||||
| VDRM | ITRMS | ISURGE | VT | IGT | VGT | IHOLD | tq | dv/dt | ||
| 230 | 700 | 8 | 90 | 2.16 | 50 | 2 | 100 | 1.8 | 400 | ![]() |
| 231 | 600 | 8 | 90 | 2.16 | 50 | 2 | 100 | - | 400 | |
| NTE Type No. |
Description and Application |
Repetitive Peak Forward Off-State Voltage (Volts) |
Maximum Ratings | Typical Turn-On Delay Time (mS) |
Typical Turn-On Rise Time (mS) |
Typical Holding Current (mA) |
Package Style | ||||
| On-State Anode Current (Amps) |
Surge On-State Current (Amps) |
On-State Voltage (Volts) |
Gate Trigger Voltage (Volts) |
Gate Trigger Current (mA) | |||||||
| VDRM | IT | ITSM | VT | VGT | IGT | td | trr | IHOLD | |||
| 276 | SCR, Gate Turn Off TV Application | 1250 | 5 | 80 | 5.3 | 1.5 | 120 | 0.2 | 1.3 | 300 | ![]() |
| NTE Type No. |
Description and Application |
Maximum Ratings | Typical Turn-Off Time (µs) |
Typical Holding Current (mA) |
Package Style | ||||
| RMS On-State Current (Amps) |
Surge Current (Amps) |
Repetitive Peak Forward Off-State Voltage (Volts) |
Gate Turn-Off Current (mA) |
Gate Turn-Off Voltage (Volts) | |||||
| ITRMS | ITSM | VDRM | IGT | VGT | tq | IHOLD | |||
| 308 | TV Horizontal Deflection & Commutating Switch |
8 | 80 | 800 | 50 | 2 | 5.1 | 50 | ![]() |
| 310 | TV Horizontal Deflection & Trace Switch |
8 | 80 | 800 | 50 | 2 | 2.9 | - | |
| 308P | TV Horizontal Deflection & Commutating Switch |
8 | 80 | 700 | 45 | 4 | 4.2 | - | ![]() |
| 310P | TV Horizontal Deflection & Trace Switch |
8 | 80 | 750 | 40 | 4 | 2.4 | - | |
DESCRIPTION:
The NTE308 and NTE310 series integrated thyristor/rectifiers are all-diffused power monolithic circuits that incorporate a silicon controlled rectifier and a silicon rectifier on a common pellet. The NTE308 series types are used as bipolar switches to control horizontal yoke current during the beam trace interval; the NTE310 series types are used as commutating switches to initiate trace-retrace switching.