LM1851 |
Ground Fault Interrupter |
Contents |
The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments. Ground fault currents greater than a presettable threshold value will trigger an external SCR-driven circuit breaker to interrupt the AC line and remove the fault condition. In addition to detection of conventional hot wire to ground faults, the neutral fault condition is also detected. Full advantage of the U.S. UL943 timing specification is taken to insure maximum immunity to false triggering due to line noise. Special features include circuitry that rapidly resets the timing capacitor in the event that noise pulses introduce unwanted charging currents and a memory circuit that allows firing of even a sluggish breaker on either half-cycle of the line voltage when external full-wave rectification is used. |
|
Title | Size (in Kbytes) | Date | View Online |
Download |
Receive via Email |
---|---|---|---|---|---|
LM1851 Ground Fault Interrupter | 165 Kbytes | 7-Jan-96 | View Online | Download | Receive via Email |
Part Number | Package | Status | Models | Samples & Electronic Orders | Budgetary Pricing | Std Pack Size | Package Marking | |||
---|---|---|---|---|---|---|---|---|---|---|
Type | # pins | SPICE | IBIS | Quantity | $US each | |||||
LM1851M | SOIC NARROW | 8 | Full production | N/A | N/A | | 1K+ | $0.4500 | tube of 95 | [logo]¢2¢T LM 1851M |
LM1851MX | SOIC NARROW | 8 | Full production | N/A | N/A | | 1K+ | $0.4500 | reel of 2500 | [logo]¢2¢T LM 1851M |
LM1851N | MDIP | 8 | Full production | N/A | N/A | | 1K+ | $0.4500 | tube of 40 | [logo]¢U¢Z¢2¢T LM 1851N |