June 5, 1997 Schmitt trigger has dynamic thresholdIsaac Eng, GSI Inc, Ottawa, ON, Canada Schmitt triggers usually switch only at predefined static setpoints. For example, to allow user-defined setpoints, you can use a comparator in a standard hysteresis configuration (Figure 1). However, the design in Figure 2 allows dynamic setpoints, which are beneficial for variable-noise applications. This circuit is useful for rejecting noise that fluctuates in amplitude. The circuit in Figure 2 has a low component count and uses common parts. VLO and VHI are the low and high setpoints, respectively, which you can change dynamically. VIN drives the negative input of comparator LM311, which compares this signal to the noninverting input voltage that comes from the output of the CD4053 analog multiplexer. The multiplexer's output voltage (active threshold) switches depending on the state of VOUT, just as in a regular Schmitt trigger. VCC and VEE can be 5V and 5V, respectively. (DI #2030) |
|||||
|
|||||
|
|||||