    CIRCUIT LAB
 

Capacitance Bridge
The circuit of a simple capacitor tester based on bridge principle is described here. The use of a capacitance bridge is illustrated with the help of Fig.1. Fixed capacitor C1 and unknown capacitor Cx form the two arms of the bridge. The other two arms of the bridge are formed by potentiometers RA and RB. Whenever the bridge is not balanced, an AF voltage appears across points V1 and V2, and hence a tone is heard in the ear-piece. By adjusting the potentiometers RA and RB the potential at points V1 and V2 can be made equal, in which case no tone is available in the ear-piece. Under such conditions the bridge is said to be balanced. The value of the unknown capacitor Cx can be calculated using the formula: Cx/C1=RA/RB, or Cx = C1 x (RA/RB). Please note, here RA and RB denote the in-circuit resistances of respective potmeters. The actual circuit utilising the above-mentioned principle is shown in Fig.2. A multivibrator using transistors T1 and T2 forms an AF oscillator circuit which provides an AC voltage to the bridge. Here the unknown capacitor is connected across point B and one end of fixed capacitor using crocodile clips. The points A and B shown here are the same as those shown in Fig.1. Potentiometer VR1 gets divided into two variable resistors RA and RB which form two arms of the bridge. When the supply is connected to the circuit, a tone is heard in the ear-piece if the bridge is unbalanced. The arm of potentiometer VR1 is adjusted in such a way that a null voltage is obtained across the ear-piece and it stops producing the tone. For accurate calibration of the circuit the following procedure should be adopted: 1. Use a fixed capacitor of, say, 100 pF for the known capacitor (C1) and use capacitors of known different values such as 10 pF, 22 pF, 33 pF, 47 pF, 82 pF, etc for the unknown capacitor (one at a time). 2. For each capacitor connected in place of Cx, vary VR1 to obtain nil tone in the ear-piece and mark VR1 position in terms of the capacitor used for Cx. Thus different positions of VR1 will signify different values of the unknown capacitor. 3. For changing the range use a capacitor which is, say, ten times the value of fixed capacitor used in step 1. The values of unknown capacitors will also increase by ten times for the same position of VR1. The bridge can measure values up to about 10 nF in different ranges.


Click on the Image for its larger version



 

This site is best viewed in 800 x 600 resolution.
©1997 copyright 2000-01, EFY Enterprises Pvt. Ltd.
|    Privacy Policy   |   Copyright Policy   |

Website Designed & Maintained by: EFY Digital