Figure 2
Component Human-body model (MIL-STD-883 method 3015.7) Machine model (IC-121, EIAJ) IEC 1000-4-2
R1 (Megohms) 1 to 10 1 50 to 100
R2 (ohms) 1500±1% 0 330
C1 (pF) 100±10% 200±5% 150
Substituting different component values for R1, R2, and C1 yields discharge circuits known as the human-body model, the machine model, and the IEC 1000-4-2 model (human holding a metallic object).