A FAMILY OF HIGH PERFORMANCE, RUGGEDIZED INTEGRATED DETECTORS.
Spectra design concept
Maximum optical performance
- Improved pulse height resolution, high light output
Ruggedized design
- Vibration, shock and temperature
High Performance Integrated Detectors
Features
- Completely sealed system
- Operates to 150°C
- PHR 7.5% (10.5% at 150°C)
- Vibration, shock qualified
*Standard geoline detectors start at 11% or 12% and go to 14% plus at 150ºC!
Design qualification
Temperature Cycle (Pre-test)
- Thermal cycle unit from room temperature to 175°C.
- Test for functionality prior to and post thermal cycle.
Impact Shock
- 100g @ 11ms - 3 shocks; 2 axes (X, ±Z); 9 total shocks.
Vibration
- Random vibration bandwidth 50-500Hz per the following power spectral density
profile:
- 50-80Hz @ 6db/Octave
- 80-500Hz @ 0db/Octave
- Level: 5grms
- Duration: 240 minutes/axis; 3 axes total (X,Y & Z)
- Temperature: 150°C to 10% (165°C)
- Post Test System Performance: Not to degrade more than 10%
Qualification
Unit Performance
Pre and Post - Thermal cycle plateau performance:
- Pulse Height - 1570 Vs. 1451
- Pulse Height Resolution - 7.9 Vs. 7.5% PHR
Pre and Post - Vibration plateau performance:
- Plateau start voltage - 1200 Vs. 1250 volts
- Plateau length - 150 Vs. 250 volts
Spectra Test Results
Standard Wireline and MWD Designs Vs. Spectraline Results
Pulse Height - 1130 Vs. 1451 @ operating voltage of 1500 Vs. 1250 volts
Pulse Height Resolution - 9.7 Vs. 7.5% PHR
Standard Wireline and MWD designs vs. Spectraline results
356 keV Region of interest
- Spectraline FWHM 8.8%
- Aluminum window STD design FWHM 11.5%
80 keV Region of Interest
- Spectraline FWHM 17.1%
- Aluminum entrance window STD design FWHM 22.1%
Availability
Wireline and multiphase flow detectors accepting prototype orders now - leadtime 14 weeks.
MWD detector available Q1 1999.
Measurement While Drilling
- Rated to 1000g shocks and 20grms vibration
- Designed to prevent counts under vibration.
- Rated up to +175°C.
*See Major Features
Wireline
- Rated to 100g shocks and 5 grms vibration
- Rated to +90°C or +175°C.
*See Major Features
Multi-Phase Flow Metering
Shock and vibration specifications depend on sub-application -subsea, platform or downhole. Temperature ratings from +50°C to +175°C.
*See Major Features
Major Features:
- Higher light output (than standard ruggedized assemblies)
- Improved Pulse Height Resolutions
- Reduced Power Consumption
- Lower operating voltage
- Reduced plateau start voltage
- Improved plateau charteristics
- Higher signal to noise ratio
- Reduced overall weight
- Unified hermetic package
[Home] [History] [Ref. Library] [News] [Bicron Home Page]