Introducing the SpectraTM series of integrated high performance OIL Exploration and Production gamma detectors

Designed specifically to meet and exceed MWD, Wireline and Multi-Phase Flow Metering application specifications, the new series offers the performance of the best “lab type” detectors in an equivalent ruggedized package.

SPECTRATM SERIES
Detector assembly


Major Features:
• 20% to 30% more light (than standard
ruggedized assemblies)
• Improved Pulse Height Resolution
• Reduced Power consumption
• Lower operating Voltage
• Reduced plateau start Voltage
• Improved plateau characteristics
• Higher signal to noise ratio
• Reduced overall weight
• Unified hermetic package

 


For MWD
Rated to 1000g shocks & 20grms vibration Designed to prevent counts under vibration. Rated up to +175°C.


For Wireline
Rated to 100g shocks & 5grms vibration Rated to +90°C or +175°C.


For Multi-Phase Flow Metering
Rated to 100g shocks & 5grms vibration Optimized for low energy measurements. Temperature ratings from +50°C to +175°C.

Performance Comparison

Pulse Height Resolution
at room temp.
Energy
SpectralineTM
standard wireline
lab grade detector
Ba-133
81keV
17.0%
23.0%
10.7%
356keV
9.3%
11.5%
8.7%
Cs-137
661.6keV
7.5%
9.7%
6.7%
Pulse Height Resolution
at +150C
Energy
SpectralineTM
standard wireline
lab grade detector
Cs-137
661.6keV
10.5%
14.0%
N/A
Pulse Height at +150°C, Cs-137
661.6keV
1451
1130
Operating Voltage
1250V
1500V
1000V

 

Ba-133 Spectra

 

[Home] [History] [Ref. Library] [News] [Bicron Home Page]
[Spectra Series] [Glossary]
[Integrated Detector Solutions Home Page] [Innova Home Page]