Introducing the SpectraTM series of integrated high performance OIL Exploration and Production gamma detectors
Designed specifically to meet and exceed MWD, Wireline and Multi-Phase Flow Metering application specifications, the new series offers the performance of the best lab type detectors in an equivalent ruggedized package.
SPECTRATM SERIES
Detector assembly
Major Features:
20% to 30% more light (than standard
ruggedized assemblies)
Improved Pulse Height Resolution
Reduced Power consumption
Lower operating Voltage
Reduced plateau start Voltage
Improved plateau characteristics
Higher signal to noise ratio
Reduced overall weight
Unified hermetic package
For MWD
Rated to 1000g shocks & 20grms vibration Designed to prevent counts under vibration. Rated up to +175°C.
For Wireline
Rated to 100g shocks & 5grms vibration Rated to +90°C or +175°C.
For Multi-Phase Flow Metering
Rated to 100g shocks & 5grms vibration Optimized for low energy measurements. Temperature ratings from +50°C to +175°C.
Performance Comparison
Pulse Height Resolution
at room temp.
|
Energy
|
SpectralineTM
|
standard wireline
|
lab grade detector
|
Ba-133
|
81keV
|
17.0%
|
23.0%
|
10.7%
|
|
356keV
|
9.3%
|
11.5%
|
8.7%
|
Cs-137
|
661.6keV
|
7.5%
|
9.7%
|
6.7%
|
Pulse Height Resolution
at +150C
|
Energy
|
SpectralineTM
|
standard wireline
|
lab grade detector
|
Cs-137
|
661.6keV
|
10.5%
|
14.0%
|
N/A
|
Pulse Height at +150°C, Cs-137
|
661.6keV
|
1451
|
1130
|
|
Operating Voltage
|
|
1250V
|
1500V
|
1000V
|
Ba-133 Spectra
[Home] [History] [Ref. Library] [News] [Bicron Home Page]
[Spectra Series] [Glossary]
[Integrated Detector Solutions Home Page] [Innova Home Page]
|