excerpts from a Rockwell Modem spec sheet
INTRODUCTION
Calling Number Delivery (CND), better known as Caller ID, is a telephone service intended for residential and small business customers. It allows the called Customer Premises Equipment (CPE) to receive a calling party's directory number and the date and time of the call during the first 4 second silent interval in the ringing cycle. (i.e. Between the first and second ring) The customer must contact Bellcore Client Company to initiate CND service.
[outdated information removed by wd]
[outdated information removed by wd]
PARAMETERS
The data signalling interface has the following characteristics:
(I have copied this data as presented. I believe the transmission level is meant to be -13.5 dBm.)
PROTOCOL
The protocol uses 8-bit data words (bytes), each bounded by a start bit and a stop bit. The CND message uses the Single Data Message format shown below.
CHANNEL SEIZURE SIGNAL
The channel seizure is 30 continuous bytes of 55h (01010101) providing a detectable alternating function to the CPE (i.e. the modem data pump).
CARRIER SIGNAL
The carrier signal consists of 130 +/- 25 mS of mark (1200 Hz) to condition the receiver for data.
MESSAGE TYPE WORD
The message type word indicates the service and capability associated with the data message. The message type word for CND is 04h (00000100).
MESSAGE LENGTH WORD
The message length word specifies the total number of data words to follow.
DATA WORDS The data words are encoded in ASCII and represent the following information:
If the calling party's directory number is not available to the terminating central office, the data word field contains an ASCII "O". If the calling party invokes the privacy capability, the data word field contains an ASCII "P".
CHECKSUM WORD
The Checksum Word contains the twos complement of the modulo 256 sum of the other words in the data message (i.e., message type, message length, and data words). The receiving equipment may calculate the modulo 256 sum of the received words and add this sum to the reveived checksum word. A result of zero generally indicates that the message was correctly received. Message retransmission is not supported.
EXAMPLE CND SINGLE DATA MESSAGE
An example of a received CND message, beginning with the message type word, follows:
04 12 30 39 33 30 31 32 32 34 36 30 39 35 35 35 31 32 31 32 51
DATA ACCESS ARRANGEMENT (DAA) REQUIREMENTS To receive CND information, the modem monitors the phone line between the first and second ring bursts without causing the DAA to go off hook in the conventional sense, which would inhibit the transmission of CND by the local central office. A simple modification to an existing DAA circuit easily accomplishes the task.
(The original Rockwell data sheet includes the suggested schematic diagram.)
MODEM REQUIREMENTS Although the data signalling interface parameters match those of a Bell 202 modem, the receiving CPE need not be a Bell 202 modem. A V.23 1200 bps modem receiver may be used to demodulate the Bell 202 signal. The ring indicate bit (RI) may be used on a modem to indicate when to monitor the phone line for CND information. After the RI bit sets, indicating the first ring burst, the host waits for the RI bit to reset. The host then configures the modem to monitor the phone line for CND information.
(I'm skipping some Rockwell-specific information here.)
According to Bellcore specifications, CND signalling starts as early as 300 mS after the first ring burst and ends at least 475 mS before the second ring burst
APPLICATIONS
Modem manufacturers will soon be implementing new modem features based on CND information as this service becomes widely available.
Once CND information is received the user may process the information in a number of ways.
REFERENCES
For more information on Calling Number Delivery (CND), refer to Bellcore publications TR-TSY-000030 and TR-TSY-000031.
To obtain Bellcore documents contact: