B&B Converters for the Industrial Bus World

What is an industrial bus? Traditionally, the industrial bus has been used to allow a central computer to communicate with a field device. The central computer was a mainframe or a mini (PDP11) and the field device could be a discreet device such as a flow meter, or temperature transmitter or a complex device such as a CNC cell or robot. As the cost of computing power came down, the industrial bus allowed computers to communicate with each other to coordinate industrial production.

INTERBUS-S, Modbus, BITBUS/IEEE1118, PROFIBUS, Optomux, Data Highway DH, P-NET, DMX512, Series 90, SNP and SNPx, SUCOnet-K1, Measurement Bus/DIN 66348As with human languages, many ways were devised to allow the computers and devices to communicate and, as with their human counterpart, most of the communication is incompatible with any of the other systems. The incompatibility can be broken into two categories: the physical layer and the protocol layer.

The physical layer and the protocol layer can be defined using the phone system as an example. Any spoken language can be carried over a phone line. As long as both the speaker and the listener(s) understand the language, communication is possible. The phone line is not concerned with the meaning of the signal that it carries, it is merely moving those signals from one point to another physically. This is the physical layer, the conduit in which communications pass from one point to another. On the other hand, the speaker and listener(s) are concerned with what is transported over the phone line. If the speaker is talking in Spanish and the listener(s) are only fluent in English, communication is not possible. Although the physical layer is working, the language or “protocol” is not correct, and communications cannot exist. The industrial world has developed a variety of different physical and protocol communications standards. A list of all of them would fill the rest of this article, so we will limit this discussion to industrial buses using the RS-232 and RS- 422/485 standards for their physical layer.

The greatest difference between RS-232 and RS-422/485 is the way information is transmitted. (See Technical Article: Getting from Here to There: Serial Communications Systems for more information) RS-232 uses a single-ended, bipolar voltage to move data between two points. RS-422/485 uses a balance differential pair to accomplish this same task. The advantage of using RS-422/485 in an industrial environment is greater noise immunity. This allows a greater distance between the transmitter and receiver. There is a downside to the greater distances provided by RS-422/485- the “difference of potential” between end points.

Industrial buses cover a large area. Often different areas of the network are supplied by different power sources. Even though all of the sources are grounded, a voltage difference can exist between the grounds of these voltage sources. This voltage difference can upset the data line in an RS-422/485 bus by pushing the signal voltage out of range and, in some cases, an excess voltage can damage equipment. Another source of excess voltage potential can be caused by intermittent sources. Power line surges and lightning are causes of this type of disturbance, but other causes, such as large electric motors starting and stopping, can temporarily affect the ground reference voltage. The solution to this problem is to employ RS-422/485 devices that provide isolation between different parts of the network. (See Technical Article: Data Line Isolation Theory for more information) Additional protection can be achieved by using a fiber optic link between the network and areas known for voltage problems such as a power house or a water treatment plant.

Two popular industrial buses that use the RS-232 and RS-422/ 485 standards are Modbus and Data Highway. Modbus was developed by Modicon for its line of PLC’s, up to and including the 984 line of controllers. Modbus can be configured for either RS-232 or RS-485 in a 4-wire mode. (Note: Modbus Plus is not RS-232 or RS-485 compatible). Data Highway is the name of the industrial bus produced by Allen-Bradley and is used on some SLC 500 controllers. An RS-485 port is also available on some PLC-2, 3 and 5 controllers. Consult the manual provided with your controller to be certain of the type of bus supported. The industrial buses that adhere to the RS-232 and RS-422/485 standard are listed below along with products that are compatible with various industrial buses. B&B products support these buses at the physical layer only and are mainly used as repeaters, line extenders and isolators. B&B also offers a custom design service to solve particular problems that arise from industrial buses.

B&B Product Compatibility with Industrial Buses
Industrial
Bus Name
Manu-
facturer
B&B Product
Compatibility
Recommended
Converter
RS-232/485
Recommended
Repeater/
Isolator
Protocol
INTERBUS-S   Remote Bus ONLY
(Local Bus is NOT compatible)
  485OP
485OPDR
Remote Bus is RS-485
Baud=500 kbps
Full Duplex
Modbus Modicon Modbus
(Modbus+ is NOT compatible)
485OTLED*
485LDRC*
485OP
232SPHI4
485OPDR
Modbus can be configured for
RS-485(4-wire) or RS-232
Baud=50 to 19200 bps
Parity: even, odd, none
BITBUS/
IEEE1118
  BITBUS/IEEE1118 485OTLED*
485LDRC*
485OP
485OPDR
BITBUS is RS-485
Baud(Kbps)=375, 62.5
PROFIBUS   PROFIBUS-DP,
PROFIBUS-FMS
(PROFIBUS-PA is NOT compatible)
485OTLED*
485LDRC
485OP
485OPDR
PROFIBUS-DP, FMS is RS-485
Baud (kbps) = 9.6, 19.2, 93.75, 187.5, 500
2-wire
Optomux Opto 22 Optomux 485OTLED
485LDRC
485OP
485OPDR
Optomux is RS-422/485
Baud=38.4 kbps
4-wire
Data Highway, DH Allen-Bradley Data Highway, DH 485OTLED*
485LDRC*
485OP
485OPDR
Data Highway, DH, are RS-485
Baud(kbps)=57.6, 115, 230.4
2-wire
P-NET   P-NET 485OTLED
485LDRC
485OP
485OPDR
P-NET is RS-485
Baud=76.8 kbps
DMX512 USITT DMX512
(AMX192 is NOT compatible)
  485OP
485OPDR
DMX512 is RS-485
Baud=250 kbps
Series 90 (SNP)
and (SNPx)
GE Fanuc Series 90 (SNP) (SNPx) 485OTLED
485LDRC
485OP
485OPDR
Series 90 uses RS-232, RS-422, RS-485
SUCOnet-K1 Moeller SUCOnet-K1   485OP
485OPDR
SUCOnet-K1 is RS-485
2-wire
Baud=187.5 kbps
Measurement Bus DIN 66348   Measurement Bus 485OTLED*
485LDRC*
485OP
232SPHI4
485OPDR
Measurement Bus RS-485 and RS-232
Baud=110 bit/s to 1Mbit/s
4-wire
*The 485OTLED and 485LDRC are rated to 115.2 kbps.
B&B offers a Fiber Optic Modem (FOSTC) and a DIN rail version (FOSTCDR) to extend a network or single drop to over 2.5 miles.
If you have a serial interface problem B&B can help with a custom product to meet your requirements. In-house engineering and manufacturing allows B&B to develop a custom product quickly and at a cost that may pleasantly surprise you.

 

 

 
What do you think of our site?
Copyright © 2001 B&B Electronics Mfg Co, All Rights Reserved
707 Dayton Road, Ottawa, IL 61350 USA
Phone: 815-433-5100
B&B Electronics Ltd. 
 

Shop from our catalog...      
 

RS-232 to RS-485 Isolated Converter, LEDs, DB25
RS-232 to RS-485 Isolated Converter, LEDs, DB25
485OTLED
 
RS-232 to RS-485 Isolated Converter, LEDs, DB9
RS-232 to RS-485 Isolated Converter, LEDs, DB9
485OT9L
 
RS-232 to RS-422/485 Isolated Converter, DIN Mount, LEDs
RS-232 to RS-422/485 Isolated Converter, DIN Mount, LEDs
485LDRC